4PRP

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.6 298 18% PEG 3350, 0.2M LiSO4 and 0.1M Na-Citrate, pH 5.6, VAPOR DIFFUSION, temperature 298K
Unit Cell:
a: 45.143 Å b: 62.599 Å c: 97.812 Å α: 92.040° β: 102.530° γ: 109.700°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.67 Solvent Content: 53.98
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.5000 47.3600 32834 1669 97.1700 0.1829 0.2287 49.6900
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.500 94.812 97.200 ? 0.082 11.900 3.800 32843 32843 0 -3 52.980
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.500 2.640 98.000 ? 0.490 1.400 3.900 4832
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.984 Australian Synchrotron MX2
Software
Software Name Purpose Version
SCALA data scaling 3.3.15
PHASER phasing .
PHENIX refinement .
PDB_EXTRACT data extraction 3.14
Blu-Ice data collection ice
XSCALE data scaling .
BUSTER refinement 2.10.0