X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 291 25% (w/v) PEG4000, 200 mM calcium chloride and 100 mM Tris-HCl, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 291K
Unit Cell:
a: 41.524 Å b: 77.013 Å c: 82.636 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.40 Solvent Content: 48.74
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.950 38.507 19546 1013 97.90 0.1830 0.2226 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.95 38.51 98.6 0.047 ? 16.2 3.5 19546 19546 0.0 0.0 35.8
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.95 2.06 97.5 ? ? 2.2 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SOLEIL BEAMLINE PROXIMA 1 1.28255 SOLEIL PROXIMA 1
Software
Software Name Purpose Version
Proxima data collection 1 SOLEIL
MOLREP phasing .
PHENIX refinement (phenix.refine: 1.8_1069)
XDS data reduction .
XDS data scaling .