X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 273 0.1M ADA (Hampton Research), 0.1M lithium acetate, 20% glycerol, 2% (v/v) PEG 400 and 8% (v/v) PEG 4000 , pH 6.5, LIQUID DIFFUSION, temperature 273K
Unit Cell:
a: 42.221 Å b: 48.078 Å c: 64.051 Å α: 88.44° β: 78.68° γ: 71.34°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 1.99 Solvent Content: 38.07
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.654 39.209 13245 650 98.07 0.1834 0.2549 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.654 40 98 0.06 ? 12.77 2 13515 13245 2 4 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ALS BEAMLINE 8.2.2 0.979 ALS 8.2.2
Software
Software Name Purpose Version
HKL-2000 data collection .
PHASER phasing .
PHENIX refinement (phenix.refine: 1.8.1_1161)
HKL-2000 data reduction .
HKL-2000 data scaling .