X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 295 0.1 M Tris HCl pH 8.5, 25%(w/v) polyethylene glycol (PEG) 3350, microbatch, temperature 295K
Unit Cell:
a: 74.023 Å b: 82.453 Å c: 164.324 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.94 Solvent Content: 58.11
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.600 29.100 30999 1503 97.88 0.2368 0.2713 55.926
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.35 50 96.7 ? ? ? ? ? 41340 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.35 2.39 77.9 ? ? 1.7 3.1 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PAL/PLS BEAMLINE 4A 1.0000 PAL/PLS 4A
Software
Software Name Purpose Version
HKL-2000 data collection .
MOLREP phasing .
PHENIX refinement (phenix.refine: 1.8.4_1496)
HKL-2000 data reduction .
HKL-2000 data scaling .
Feedback Form
Name
Email
Institute