X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 291 100 mM Bis-Tris, 350 mM Sodium Acetate, 16% PEG3350, pH 6.5, VAPOR DIFFUSION, SITTING DROP, temperature 291K
Unit Cell:
a: 54.627 Å b: 78.873 Å c: 54.324 Å α: 90.00° β: 105.94° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.32 Solvent Content: 47.00
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.295 23.51 19178 1924 96.39 0.2002 0.2610 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.295 23.51 96.4 ? ? ? ? 19178 19178 -4 0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU MICROMAX-007 HF 1.5418 ? ?
Software
Software Name Purpose Version
HKL-2000 data collection .
PHENIX model building .
PHENIX refinement (phenix.refine: 1.8.2_1309)
HKL-2000 data reduction .
HKL-2000 data scaling .
PHENIX phasing .