X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.2 293 PEG 4000, CaCl2, glycerol, pH 7.2, VAPOR DIFFUSION, temperature 293K
Unit Cell:
a: 78.548 Å b: 101.692 Å c: 132.422 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: I 2 2 2
Crystal Properties:
Matthew's Coefficient: 2.39 Solvent Content: 48.51
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.9500 29.2200 11342 543 98.6300 0.2502 0.2732 124.6155
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.950 29.22 98.800 0.061 ? 16.800 6.700 ? 11344 ? ? 122.390
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.950 3.110 100.000 ? ? 2.9 7.000 1631
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID23-1 1.0723 ESRF ID23-1
Software
Software Name Purpose Version
MOSFLM data reduction .
SCALA data scaling 3.3.20
PHASER phasing .
BUSTER-TNT refinement .
PDB_EXTRACT data extraction 3.11
BUSTER refinement 2.10.0