X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 9.0 289 0.1M Glycine pH 9.0, 31% PEG 400, 0.15M magnesium chloride, 0.4M sodium chloride, VAPOR DIFFUSION, HANGING DROP, temperature 289K
Unit Cell:
a: 71.071 Å b: 71.071 Å c: 143.341 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 32 2 1
Crystal Properties:
Matthew's Coefficient: 2.96 Solvent Content: 58.40
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.900 28.514 9604 963 98.09 0.2368 0.2813 54.8397
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.9 50 99.0 ? ? ? ? 49230 48998 2.0 2.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.90 3.00 99.9 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SEALED TUBE RIGAKU MICROMAX-007 HF 1.5418 ? ?
Software
Software Name Purpose Version
HKL-2000 data collection .
PHENIX model building (Phaser-MR: 1.8.1_1168)
PHENIX refinement (phenix.refine: 1.8.1_1168)
HKL-2000 data reduction .
HKL-2000 data scaling .
PHENIX phasing (Phaser-MR: 1.8.1_1168)
Feedback Form
Name
Email
Institute
Feedback