X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7 298 1.9M Sodium/Potassium Phosphate, Batch method, pH 7, EVAPORATION, temperature 298K
Unit Cell:
a: 106.040 Å b: 52.229 Å c: 106.381 Å α: 90.00° β: 114.27° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.15 Solvent Content: 42.84
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.242 45.073 48746 1980 99.27 0.1769 0.2322 46.6798
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.920 100.000 93.500 0.049 ? 17.500 2.900 ? 50708 ? ? 35.600
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.920 1.950 95.900 ? ? ? 2.900 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 21-ID-D 1.07 APS 21-ID-D
Software
Software Name Purpose Version
SCALEPACK data scaling .
PHENIX refinement 1.8.3_1479
PDB_EXTRACT data extraction 3.11