X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 293 100 mM NaPi, pH7.0, 100 mM NaCl, 32-34% PEG300, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 87.897 Å b: 88.383 Å c: 81.311 Å α: 90.00° β: 94.84° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.71 Solvent Content: 54.67
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 3.1 38.796 10972 529 95.14 0.2146 0.2350 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
3.1 40 95.9 0.123 ? 11.3 2.9 11463 10993 ? -3 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 3.1 3.21 80.4 ? ? 1.5 2.4 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 24-ID-E 0.979 APS 24-ID-E
Software
Software Name Purpose Version
ADSC data collection Quantum
PHASER phasing .
PHENIX refinement (phenix.refine: 1.8.1_1168)
HKL-2000 data reduction .
HKL-2000 data scaling .