X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.6 291 1M ammonium phosphate, 100mM tri-sodium citrate, pH 5.6, VAPOR DIFFUSION, HANGING DROP, temperature 291K
Unit Cell:
a: 34.026 Å b: 58.514 Å c: 136.695 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 1.63 Solvent Content: 24.59
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.006 44.449 17404 1754 91.48 0.2126 0.2580 39.75
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.0 50.0 94.6 ? 0.151 20.8 13.7 18054 18054 0.0 0.0 32.6
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.0 2.07 76.2 ? 0.781 2.5 10.6 1394
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON NSLS BEAMLINE X29A 1.075 NSLS X29A
Software
Software Name Purpose Version
CBASS data collection .
PHENIX model building (AutoMR)
PHENIX refinement (phenix.refine: 1.8.2_1309)
HKL-2000 data reduction .
HKL-2000 data scaling .
PHENIX phasing (AutoMR)
Feedback Form