X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 295 22% PEG 8000, 100mM MOPS, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 295K
Unit Cell:
a: 77.282 Å b: 59.906 Å c: 119.932 Å α: 90.00° β: 102.63° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.61 Solvent Content: 52.96
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.909 19.891 21687 1083 91.06 0.2322 0.2772 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.9 20 91.4 0.068 0.068 17.3 3.2 22868 21741 0 0 73.3
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.9 3.0 76.9 ? 0.272 3.29 2.9 2094
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SPRING-8 BEAMLINE BL41XU 1.00599 SPring-8 BL41XU
Software
Software Name Purpose Version
HKL-2000 data collection .
PHASER phasing .
PHENIX refinement (phenix.refine: 1.8.2_1309)
HKL-2000 data reduction .
SCALEPACK data scaling .
Feedback Form
Name
Email
Institute
Feedback