X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 292 0.1M MES, 0.2M MgCl2, 10% PEG 4000, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 292K
Unit Cell:
a: 90.832 Å b: 90.832 Å c: 111.987 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: I 4
Crystal Properties:
Matthew's Coefficient: 2.68 Solvent Content: 54.07
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.1000 24.5780 23507 1777 88.6700 0.1769 0.2155 19.3860
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.1 30 89.24 ? ? ? 6.4 ? 23659 0 -3.0 23.58
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 ? K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU MICROMAX-007 1.54 ? ?
Software
Software Name Purpose Version
DENZO data reduction .
SCALEPACK data scaling .
PHASER phasing 2.5.3
PHENIX refinement 1.8.2_1309
PDB_EXTRACT data extraction 3.11
HKL-2000 data collection .