X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.6 289 15% PEG 6000, 100 mM sodium acetate, pH 4.6, VAPOR DIFFUSION, HANGING DROP, temperature 289K
Unit Cell:
a: 36.090 Å b: 64.838 Å c: 68.062 Å α: 93.480° β: 94.100° γ: 100.250°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.17 Solvent Content: 43.37
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.2600 30.8564 26999 1374 95.6100 ? 0.2614 32.8138
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.260 67.700 95.700 0.069 ? 7.200 1.960 ? 27037 3.0 3.0 32.928
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.260 2.340 93.600 ? ? 2.400 1.950 2624
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 120 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU MICROMAX-007 HF 1.542 ? ?
Software
Software Name Purpose Version
d*TREK data scaling 9.7 W8RSSI
d*TREK data reduction 9.7 W8RSSI
MOLREP phasing .
PHENIX refinement .
PDB_EXTRACT data extraction 3.11
CrystalClear data collection .
CrystalClear data reduction .
CrystalClear data scaling .