X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8 298 PEG MPD, pH 8, VAPOR DIFFUSION, HANGING DROP, temperature 298K
Unit Cell:
a: 99.870 Å b: 41.110 Å c: 109.580 Å α: 90.00° β: 115.63° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.11 Solvent Content: 41.63
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.500 35.572 64346 3219 99.55 0.1659 0.1957 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.5 37 99.1 ? ? ? ? 65228 64638 -3 -3 21.12
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.5 1.59 97.5 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SOLEIL BEAMLINE PROXIMA 1 0.980110 SOLEIL PROXIMA 1
Software
Software Name Purpose Version
DNA data collection .
MOLREP phasing .
PHENIX refinement (phenix.refine: 1.7.2_869)
XDS data reduction .
XDS data scaling .