X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 293 25% PEG6000, 0.1 M Tris-HCl, pH 8.0, 4% DMSO, VAPOR DIFFUSION, temperature 293K
Unit Cell:
a: 47.592 Å b: 42.351 Å c: 76.811 Å α: 90.000° β: 105.750° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.38 Solvent Content: 48.22
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.700 20.00 31585 1608 96.60 0.1703 0.2051 21.1067
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.700 73.928 96.9 0.057 0.057 15.9 3.6 31620 31620 ? ? 18.71
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.700 1.790 82.6 ? 0.305 2.50 3.1 3897
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-2 0.933 ESRF ID14-2
Software
Software Name Purpose Version
MOSFLM data reduction .
SCALA data scaling 3.2.19
MOLREP phasing .
REFMAC refinement .
PDB_EXTRACT data extraction 3.11