X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.0 291 PEG, pH 6.0, VAPOR DIFFUSION, SITTING DROP, temperature 291K
Unit Cell:
a: 91.376 Å b: 91.376 Å c: 87.273 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 32
Crystal Properties:
Matthew's Coefficient: 3.21 Solvent Content: 61.69
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.497 24.671 28261 1428 99.92 0.1626 0.2086 41.7028
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.4970 50 99.9 ? ? ? ? 28261 28261 1.96 1.96 35.060
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.5 2.56 99.6 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SSRF BEAMLINE BL17U 0.97 SSRF BL17U
Software
Software Name Purpose Version
HKL-2000 data collection .
PHASES phasing .
PHENIX refinement (phenix.refine: 1.8.1_1168)
HKL-2000 data reduction .
HKL-2000 data scaling .