X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.5 298 5% PEG 3350, 0.2M Potassium Acetate, 0.1M MES pH5.5, vapor diffusion, hanging drop, temperature 298K
Unit Cell:
a: 81.592 Å b: 180.685 Å c: 116.069 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 2.67 Solvent Content: 53.98
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.8800 30.276 69666 1999 99.6700 0.1769 0.2146 35.8517
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.880 50.000 99.800 0.048 ? 19.500 7.100 69860 69721 0 0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.880 1.950 99.200 ? ? ? 6.500 6865
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON NSLS BEAMLINE X29A 1.0809 NSLS X29A
Software
Software Name Purpose Version
DENZO data reduction .
SCALEPACK data scaling .
PHENIX refinement 1.8_1069
PDB_EXTRACT data extraction 3.11
HKL-2000 data collection .
HKL-2000 data reduction .
HKL-2000 data scaling .
PHENIX phasing .