X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.6 289 0.2 M Ammonium tartrate dibasic, 20% w/v Polyethylene glycol 3350, pH 6.6, VAPOR DIFFUSION, SITTING DROP, temperature 289K
Unit Cell:
a: 72.006 Å b: 48.712 Å c: 194.295 Å α: 90.00° β: 97.89° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.23 Solvent Content: 44.84
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.73 48.11 125850 6346 89.7 0.184 0.221 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.73 50 89 ? ? ? ? ? 140395 12.64 1.65 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 120 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 23-ID-B 1 APS 23-ID-B
Software
Software Name Purpose Version
HKL-2000 data collection .
MLPHARE phasing .
PHENIX refinement (phenix.refine: 1.7.2_869)
HKL-2000 data reduction .
SCALEPACK data scaling .