X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.3 291.0 30% PEG4000, pH 7.3, vapor diffusion, hanging drop, temperature 291.0K
Unit Cell:
a: 57.306 Å b: 57.306 Å c: 87.528 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 41 21 2
Crystal Properties:
Matthew's Coefficient: 2.04 Solvent Content: 39.57
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION Isomorphous Replacement ? 1.03 40.52 70458 6594 94.7600 0.0906 0.1042 13.8199
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.030 47.946 96.900 0.087 0.087 18.800 10.500 70458 70458 0 0 7.7
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.030 1.090 79.400 ? 0.216 3.400 3.300 8294
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID29 0.97934 ESRF ID29
Software
Software Name Purpose Version
MOSFLM data reduction .
SCALA data scaling 3.2.19
PHENIX refinement 1.8_1069
PDB_EXTRACT data extraction 3.11
PXSOFT data collection .