X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7 277 Crystals in condition H3 from Silver Bullet screen (Hampton Research) using Tacsimate in the reservoir, pH 7, VAPOR DIFFUSION, HANGING DROP, temperature 277K
Unit Cell:
a: 128.123 Å b: 128.123 Å c: 159.362 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 42 21 2
Crystal Properties:
Matthew's Coefficient: 3.28 Solvent Content: 62.50
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT R-free 2.30 33.83 54957 2774 92.3800 0.1828 0.2318 17.6987
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.30 33.83 92.8000 ? 0.128 11.300 5.4 54972 54972 0.000 0.000 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.30 2.38 97.6 ? 0.355 3.6 4.4 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU MICROMAX-007 1.54178 ? ?
Software
Software Name Purpose Version
DENZO data reduction .
SCALEPACK data scaling .
PHENIX refinement 1.8_1069
PDB_EXTRACT data extraction 3.11
HKL-2000 data collection .
HKL-2000 data reduction .
HKL-2000 data scaling .
AMoRE phasing .