X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7 277 Crystals in condition H3 from Silver Bullet screen (Hampton Research) using Tacsimate in the reservoir, pH 7, VAPOR DIFFUSION, HANGING DROP, temperature 277K
Unit Cell:
a: 127.736 Å b: 127.736 Å c: 159.111 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 42 21 2
Crystal Properties:
Matthew's Coefficient: 3.26 Solvent Content: 62.21
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT R-free 1.6020 48.9830 166505 8478 96.8200 0.1756 0.1979 20.0344
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.60 50.00 96.900 0.096 ? 10.156 4.300 166624 166624 0.000 0.000 16.420
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.60 1.66 96.7 ? ? 3.439 4.000 16450
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SLS BEAMLINE X06DA 0.92019 SLS X06DA
Software
Software Name Purpose Version
PHENIX refinement dev_1144
PDB_EXTRACT data extraction 3.11
HKL-2000 data collection .
HKL-2000 data reduction .
HKL-2000 data scaling .
AMoRE phasing .