X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 298 1.0M sodium/potassium tartrate, 0.1M Hepes, pH 7.0, vapor diffusion, sitting drop, temperature 298K
Unit Cell:
a: 56.750 Å b: 56.750 Å c: 134.850 Å α: 90.000° β: 90.000° γ: 120.000°
Symmetry:
Space Group: P 65 2 2
Crystal Properties:
Matthew's Coefficient: 2.03 Solvent Content: 39.40
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.960 33.1690 9877 476 99.9600 0.2023 0.2394 39.6202
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.960 49.138 100.000 ? 0.103 21.100 16.700 9923 9923 0.9 0.9 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.960 2.060 100.000 ? 0.724 0.900 16.700 1380
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-4 0.977 ESRF ID14-4
Software
Software Name Purpose Version
MOSFLM data reduction .
SCALA data scaling 3.3.16
PHASER phasing .
PHENIX refinement 1.7.3_928
PDB_EXTRACT data extraction 3.11