X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.3 279 0.2M MgCl2, 0.1M Tris, 16-18% PEG3350, 3mM TCEP, pH 8.3, VAPOR DIFFUSION, HANGING DROP, temperature 279K
Unit Cell:
a: 83.017 Å b: 56.980 Å c: 135.073 Å α: 90.00° β: 93.78° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.23 Solvent Content: 44.90
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.15 35.28 67126 3384 96.91 0.22948 0.29079 22.248
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.15 50 97.2 0.095 ? 10.41 3.1 67257 67257 -1 -1 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.15 2.19 ? ? ? 1.9 2.9 3361
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.95369 Australian Synchrotron MX2
Software
Software Name Purpose Version
Blu-Ice data collection .
PHENIX model building .
REFMAC refinement 5.5.0109
DENZO data reduction .
SCALEPACK data scaling .
PHENIX phasing .