X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 293 20% PEG6000, 1 M lithium chloride, pH 8.0, SITTING DROP, temperature 293K
Unit Cell:
a: 138.007 Å b: 138.007 Å c: 113.675 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 42 21 2
Crystal Properties:
Matthew's Coefficient: 3.35 Solvent Content: 63.26
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 3.100 97.586 20157 928 98.25 0.226 0.276 60.665
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
3.000 97.586 99.000 0.127 0.127 11.200 5.900 22560 22186 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 3.16 3.33 99.7 ? 0.664 1.2 5.9 2765
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SOLEIL BEAMLINE PROXIMA 1 1.1271 SOLEIL PROXIMA 1
Software
Software Name Purpose Version
REFMAC refinement .
SCALA data scaling 3.2.19
PDB_EXTRACT data extraction 3.006
MxCuBE data collection .
XDS data reduction .
MOLREP phasing .