X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 295 Bis-Tris 0.1 M, lithium sulfate 1.6 M and magnesium sulfate 50 mM, VAPOR DIFFUSION, HANGING DROP, temperature 295K, pH 6.5
Unit Cell:
a: 66.287 Å b: 66.287 Å c: 263.662 Å α: 90° β: 90° γ: 120°
Symmetry:
Space Group: P 65 2 2
Crystal Properties:
Matthew's Coefficient: 2.36 Solvent Content: 47.78
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.9 20 9920 498 ? .232 .291 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.9 20 98 ? ? ? ? 7344 9920 2.0 2.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.9 2.97 96.1 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 200 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-1 ? ESRF ID14-1
Software
Software Name Purpose Version
ADSC data collection Quantum
CNS refinement .
HKL-2000 data reduction .
HKL-2000 data scaling .
CNS phasing .