X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.5 293 18-20% PEG 4000, 20% glycerol, 0.2M ammonium acetate, 0.1 M MES, pH 5.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 76.220 Å b: 28.420 Å c: 52.260 Å α: 90.00° β: 126.54° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 1.91 Solvent Content: 35.74
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.40 18.80 16709 892 97.89 0.13275 0.18616 14.763
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.40 18.80 98.4 0.066 0.066 10.1 3.1 ? 17632 ? ? 14.6
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.40 1.48 98.9 ? 0.375 2.9 3.3 2542
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 110 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-1 0.933 ESRF ID14-1
Software
Software Name Purpose Version
MxCuBE data collection .
PHASER phasing .
REFMAC refinement 5.5.0109
MOSFLM data reduction .
SCALA data scaling .