X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.2 295 0.1M phosphate-citrate, 0.2M NaCl, 20%(w/v) PEG 8000, pH 4.2, vapor diffusion, hanging drop, temperature 295K
Unit Cell:
a: 133.833 Å b: 142.427 Å c: 85.236 Å α: 90.00° β: 127.97° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.68 Solvent Content: 54.13
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.700 37.733 134038 2010 97.33 0.1762 0.2142 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.7 50 98 0.053 ? ? 3.8 134051 134051 0 -3 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.70 1.76 96.4 ? ? ? 3.5 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PHOTON FACTORY BEAMLINE BL-17A 1.0000 Photon Factory BL-17A
Software
Software Name Purpose Version
PHENIX refinement 1.7.3_928
PDB_EXTRACT data extraction 3.11
HKL-2000 data collection .
HKL-2000 data reduction .
SCALEPACK data scaling .
PHASER phasing .
REFMAC refinement .