X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 10.5 293 40% 2-methyl-1,3-propanediol, 0.1 M CAPS, 2mM STO1102, pH 10.5, VAPOR DIFFUSION, temperature 293K
Unit Cell:
a: 69.676 Å b: 45.383 Å c: 123.389 Å α: 90.00° β: 90.25° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.12 Solvent Content: 42.07
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.400 38.028 30110 2020 98.14 0.2241 0.2866 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.40 40.0 98.1 0.159 ? 9.1 3.6 30110 30110 0 0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.40 2.46 91.1 ? ? 3.8 3.6 1988
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-4 0.93928 ESRF ID14-4
Software
Software Name Purpose Version
MxCuBE data collection .
MOLREP phasing .
PHENIX refinement (phenix.refine: 1.7_650)
XDS data reduction .
XSCALE data scaling .