Planned Maintenance: Some services may turn out to be unavailable from 15th January, 2026 to 16th January, 2026. We apologize for the inconvenience!

X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.5 292 0.15M sodium thiocyanate, 0.1M Bis-Tris, 13% PEG3350, 2% Benzamidine, 2.5 mM ppGpp, 10 mM MnCl2, 1 mM MgCl2, pH 6.5, VAPOR DIFFUSION, HANGING DROP, temperature 292K
Unit Cell:
a: 152.164 Å b: 152.164 Å c: 38.769 Å α: 90.000° β: 90.000° γ: 120.000°
Symmetry:
Space Group: P 61
Crystal Properties:
Matthew's Coefficient: 3.43 Solvent Content: 64.12
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.005 43.9260 34635 1765 99.7300 0.1820 0.2268 36.3554
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.005 131.405 99.700 ? 0.075 ? 8.200 34635 34635 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.00 2.11 98.1 ? 0.63 3.2 7.8 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ALS BEAMLINE 8.3.1 1.115 ALS 8.3.1
Software
Software Name Purpose Version
SCALA data scaling 3.3.20
PHENIX refinement 1.7.3_928
PDB_EXTRACT data extraction 3.10
Blu-Ice data collection .
XDS data reduction .
PHENIX phasing AutoMR
Feedback Form
Name
Email
Institute
Feedback