X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 6.0 283 0.1M MES, 6-17%(W/V) PEG 2K-MME, pH 6.0, VAPOR DIFFUSION, HANGING DROP, temperature 283K
Unit Cell:
a: 98.786 Å b: 98.786 Å c: 82.431 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 61
Crystal Properties:
Matthew's Coefficient: 2.12 Solvent Content: 42.05
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION FOURIER SYNTHESIS ? 1.717 28.517 46797 2370 95.93 0.1812 0.2140 25.1097
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.717 50 96.5 ? 0.089 12.7 3.2 ? 46860 ? ? 17.020
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.72 1.75 98.5 ? 0.693 1.7 2.8 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 95 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 22-BM 1 APS 22-BM
Software
Software Name Purpose Version
HKL-2000 data collection .
PHENIX refinement (phenix.refine: 1.6.1_357)
HKL-2000 data reduction .
HKL-2000 data scaling .