X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.5 291 18% PEG 1000, 0.1 Na-Acetate pH4.5, 5% Glycerol, vapor diffusion, temperature 291K
Unit Cell:
a: 48.600 Å b: 76.920 Å c: 104.000 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.18 Solvent Content: 43.63
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.9000 44.0300 31372 1580 99.6600 0.1745 0.2194 18.2156
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.900 61.843 99.700 ? 0.079 13.500 4.600 31429 31429 2.0 2.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.900 2.000 97.900 ? 0.241 2.900 4.100 4413
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID23-2 0.976 ESRF ID23-2
Software
Software Name Purpose Version
MOSFLM data reduction .
SCALA data scaling 3.3.15
PHASER phasing 2.1.4
REFMAC refinement .
PDB_EXTRACT data extraction 3.10
DNA data collection .