X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 290 20% w/v PEG3350, 0.2 M ammonium citrate tribasic, pH 7.0, VAPOR DIFFUSION, SITTING DROP, temperature 290K
Unit Cell:
a: 68.470 Å b: 68.470 Å c: 123.870 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 43 21 2
Crystal Properties:
Matthew's Coefficient: 2.25 Solvent Content: 45.43
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.831 48.416 26675 1331 99.86 0.1702 0.1978 21.4041
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.831 48.416 100.0 0.110 0.110 18.5 13.7 26775 26775 1.0 1.0 20.1
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.831 1.930 100.0 ? 0.584 1.30 13.1 3824
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID29 0.976 ESRF ID29
Software
Software Name Purpose Version
MOSFLM data reduction .
SCALA data scaling 3.3.16
MOLREP phasing .
REFMAC refinement 5.5.0109
PDB_EXTRACT data extraction 3.10
ADSC data collection Quantum