X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8 ? PROTEIN WAS CRYSTALLIZED FROM 20% V/V GLYCEROL ETHOXYLATE, 12.5% V/V TETRAHYDROFURAN, 100 MM TRIS-HCL PH 8
Unit Cell:
a: 150.210 Å b: 150.210 Å c: 140.540 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: H 3
Crystal Properties:
Matthew's Coefficient: 2.71 Solvent Content: 54.7
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.841 47.733 26775 1330 96.04 0.2133 0.2541 50.20
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.84 47.73 96.0 0.06 ? 13.06 2.1 ? 26776 ? -3.0 55.90
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.84 2.94 94.4 ? 2.72 2.2
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 90 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON DIAMOND BEAMLINE I02 ? Diamond I02
Software
Software Name Purpose Version
PHENIX refinement (PHENIX.REFINE)
XDS data reduction .
XDS data scaling .
PHASER phasing .