X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7 293 5-7% PEG6000, 50 MM HEPES PH 7.0, 200 MM AMMONIUM ACETATE, 300 MM SODIUM ACETATE, 5 MM TCEP, VAPOR DIFFUSION, HANGING DROP, TEMPERATURE 293 K
Unit Cell:
a: 222.240 Å b: 391.580 Å c: 281.020 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: C 2 2 21
Crystal Properties:
Matthew's Coefficient: 5.2 Solvent Content: 76
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 3.60 48.95 141062 2784 99.98 0.1755 0.2062 125.34
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
3.60 48.95 100.0 0.21 ? 9.95 7.62 ? 141065 ? 0.0 79.08
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 3.60 3.69 100.0 ? 1.57 7.61
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SLS BEAMLINE X06SA ? SLS X06SA
Software
Software Name Purpose Version
BUSTER refinement 2.11.5
XDS data reduction .
XSCALE data scaling .