X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8 ? 0.06 M TRIS-HCL, PH 8, 16% PEG 550 MME, 0.01 M CACL2, 0.08 M NACL AND 0.1% NAN3
Unit Cell:
a: 94.966 Å b: 69.937 Å c: 102.347 Å α: 90.00° β: 96.97° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.7 Solvent Content: 55
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.399 30.479 251494 2003 96.09 0.1443 0.1703 13.2
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.40 30.43 96.4 0.13 ? 7.20 3.6 ? 251592 ? 2.0 8.47
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.40 1.48 95.7 ? 3.50 3.7
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-2 ? ESRF ID14-2
Software
Software Name Purpose Version
PHENIX refinement (PHENIX.REFINE)
MOSFLM data reduction .
SCALA data scaling .
MOLREP phasing .