X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 9.8 ? MICRODIALYSIS AGAINST 68-70 MM REMARK 280 PIPERAZINE PH 9.8, 28-30 MM NABR, 20-22% GLYCEROL, 9% MPD, 0.5% GALNAC. FOR DETAILS SEE REFERENCE IN REMARK 1
Unit Cell:
a: 121.360 Å b: 51.190 Å c: 210.650 Å α: 90.00° β: 105.75° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.4 Solvent Content: 42
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.95 223.61 44352 2354 87.11 0.21669 0.24433 41.961
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.35 46.89 87.1 0.14 ? 8.00 3.1 ? 46706 ? 0.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.95 3.11 59.7 ? 2.20 1.7
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SRS BEAMLINE PX9.6 ? SRS PX9.6
Software
Software Name Purpose Version
REFMAC refinement 5.7.0002
MOSFLM data reduction .
SCALA data scaling .
PHASER phasing .
Feedback Form