X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 293 0.1M Tris pH 8.0, 0.5% polyethyleneglycol monomethyl ether 5000, 0.65M Na-K phosphate tetrahydrate, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 99.524 Å b: 99.524 Å c: 126.584 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: I 41
Crystal Properties:
Matthew's Coefficient: 4.36 Solvent Content: 71.80
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.50 70.374 20584 1060 96.430 0.188 0.2212 65.546
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.50 78.30 99 0.073 0.070 8.3 10.4 21338 21338 0 0 53.970
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.50 2.64 100 ? 0.386 2.1 5.8 3117
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-1 0.934 ESRF ID14-1
Software
Software Name Purpose Version
PHENIX refinement (phenix.refine)
DNA data collection .
MOSFLM data reduction .
SCALA data scaling .
PHASER phasing .