3ZK9

X-RAY DIFFRACTION


Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 293 12.5% W/V PEG 1,000 12.5% W/V PEG 3,350, 12.5% V/V MPD; 0.1 M TRIZMA/BICINE PH 8.7 AFTER 7-10 DAYS AT 293 K, FOLLOWING STREAK-SEEDING OF PRE-EQUILIBRATED (24 HOURS) DROPS.
Unit Cell:
a: 41.040 Å b: 59.780 Å c: 62.400 Å α: 106.92° β: 103.91° γ: 97.37°
Symmetry:
Space Group: P 1
Crystal Properties:
Matthew's Coefficient: 2.21 Solvent Content: 44.31
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.45 19.46 91166 4567 95.55 0.1404 0.1646 18.42
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.45 19.46 95.5 0.03 ? 21.10 3.0 ? 91166 ? 2.0 15.97
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.45 1.47 85.5 ? 4.80 2.9
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 ? Australian Synchrotron MX2
Software
Software Name Purpose Version
BUSTER refinement 2.10.0
XDS data reduction .
Aimless data scaling .
PHASER phasing .