X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.75 277 25% PEG8000, 0.1M sodium acetate, 0.1M HEPES-NaOH, pH 7.75, VAPOR DIFFUSION, SITTING DROP, temperature 277K
Unit Cell:
a: 57.435 Å b: 60.765 Å c: 117.986 Å α: 90.00° β: 98.58° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.17 Solvent Content: 43.26
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.70 20.00 20862 1098 100.00 0.23694 0.31436 61.634
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.70 56.8 98.2 ? ? ? ? 43335 42572 0 0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.70 2.85 98.5 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 95 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PHOTON FACTORY BEAMLINE BL-5A 1.0000 Photon Factory BL-5A
Software
Software Name Purpose Version
ADSC data collection Quantum
MOLREP phasing .
REFMAC refinement 5.5.0109
XDS data reduction .
XSCALE data scaling .