X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 277 50% 2-methyl-2,4-pentanediol, 0.1M Tris-HCl, 0.2M (NH4)2HPO4, pH 8.0, VAPOR DIFFUSION, SITTING DROP, temperature 277K
Unit Cell:
a: 67.240 Å b: 54.400 Å c: 44.710 Å α: 90.00° β: 106.17° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 2.37 Solvent Content: 48.12
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.650 27.514 16812 841 89.73 0.1519 0.1689 19.6599
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.65 30 89.6 0.025 ? 22.01 2.3 ? 38021 ? ? 14.370
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.65 1.69 87.3 ? ? 10.96 2.1 1192
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
ROTATING ANODE RIGAKU MICROMAX-007 HF 1.5418 ? ?
Software
Software Name Purpose Version
CrystalClear data collection .
MOLREP phasing .
PHENIX refinement 1.8.2
XDS data reduction .
XDS data scaling .
Feedback Form
Name
Email
Institute
Feedback