X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 293 0.1M Tris-HCl, 2.9M sodium formate, pH 8.5, VAPOR DIFFUSION, SITTING DROP, temperature 293K
Unit Cell:
a: 121.737 Å b: 62.535 Å c: 79.977 Å α: 90.00° β: 127.97° γ: 90.00°
Symmetry:
Space Group: C 1 2 1
Crystal Properties:
Matthew's Coefficient: 3.23 Solvent Content: 61.89
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.9750 39.9330 33300 3235 97.3200 0.2031 0.2406 31.3538
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.97 50.0 98.8 ? 0.14 8.9 3.8 33311 33311 0 -3.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.97 2.00 77.0 ? 0.66 2.1 3.3 1295
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON AUSTRALIAN SYNCHROTRON BEAMLINE MX2 0.9537 Australian Synchrotron MX2
Software
Software Name Purpose Version
HKL-2000 data collection .
PHASER phasing .
PHENIX refinement (phenix.refine: 1.8.1_1168)
HKL-2000 data reduction .
HKL-2000 data scaling .