X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.2 293 0.1M sodium chloride, 12% MPD, 0.1M sodium acetate, pH 5.2, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 69.967 Å b: 69.967 Å c: 123.428 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 32 2 1
Crystal Properties:
Matthew's Coefficient: 2.23 Solvent Content: 44.95
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.30 50.00 15221 806 98.91 0.18349 0.20910 34.492
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.3 60.63 99.0 ? ? ? ? 16234 16072 0 0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.3 2.38 92.5 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 95.0 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PHOTON FACTORY BEAMLINE BL-17A 1.0000 Photon Factory BL-17A
Software
Software Name Purpose Version
ADSC data collection Quantum
MOLREP phasing .
REFMAC refinement 5.6.0117
HKL-2000 data reduction .
HKL-2000 data scaling .