X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 293 0.1M Tris, 50%(v/v) MPD, pH 7.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 50.133 Å b: 147.642 Å c: 55.422 Å α: 90.00° β: 104.51° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.53 Solvent Content: 51.39
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.60 19.14 100324 5070 97.9 0.176 0.188 16.7
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.6 50 99.8 0.036 ? ? 3.8 ? 102028 ? 0 17.1
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SPRING-8 BEAMLINE BL38B1 1.0000 SPring-8 BL38B1
Software
Software Name Purpose Version
ADSC data collection Quantum
CNS refinement .
HKL-2000 data reduction .
HKL-2000 data scaling .
CNS phasing .