X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.5 293 30% PEG 4000, 0.2M Lithium sulfate, 0.1M Tris-HCl, pH 8.5, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 51.03 Å b: 37.68 Å c: 52.54 Å α: 90.00° β: 105.03° γ: 90.00°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.10 Solvent Content: 41.39
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.700 30.255 21261 1092 99.01 0.2083 0.2554 33.1108
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.7 30.255 99 0.038 0.034 2.31 2.8 21277 21522 1.37 1.37 23.64
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 95 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PHOTON FACTORY BEAMLINE BL-1A 1.1 Photon Factory BL-1A
Software
Software Name Purpose Version
HKL-2000 data collection .
MOLREP phasing Auto MR
PHENIX refinement (phenix.refine: 1.7.1_743)
DENZO data reduction .
SCALEPACK data scaling .