X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.0 277 3M sodium malonate, pH 7.0, VAPOR DIFFUSION, HANGING DROP, temperature 277K
Unit Cell:
a: 50.740 Å b: 50.740 Å c: 150.770 Å α: 90.00° β: 90.00° γ: 120.00°
Symmetry:
Space Group: P 31 2 1
Crystal Properties:
Matthew's Coefficient: 3.31 Solvent Content: 62.81
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION SAD ? 2.003 10.0 15682 1580 98.77 0.2106 0.2417 ?
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.0 33.080 98.3 ? ? ? ? ? 15726 2.0 ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.0 2.1 91.0 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PHOTON FACTORY BEAMLINE BL-5A 0.9790 Photon Factory BL-5A
Software
Software Name Purpose Version
HKL-2000 data collection .
SOLVE phasing .
PHENIX refinement (phenix.refine: 1.5_2)
HKL-2000 data reduction .
HKL-2000 data scaling .