X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 5.1 293 26% w/v PEG2000, 0.2 M ammonium acetate, pH 5.1, SITTING DROP, temperature 293K
Unit Cell:
a: 48.012 Å b: 85.163 Å c: 66.127 Å α: 90.000° β: 107.100° γ: 90.000°
Symmetry:
Space Group: P 1 21 1
Crystal Properties:
Matthew's Coefficient: 2.19 Solvent Content: 43.88
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 1.600 45.89 66973 4855 99.99 0.1848 0.2019 19.3318
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.597 45.890 ? ? ? ? ? 67287 67280 2.0 2.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.597 1.66 100 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 21-ID-D 1.0 APS 21-ID-D
Software
Software Name Purpose Version
DENZO data reduction .
REFMAC refinement 5.5.0072
PDB_EXTRACT data extraction 3.10
HKL-2000 data collection .
SCALEPACK data scaling .
PHASES phasing .