X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.75 291 23% PEG 4000, 0.1 M SODIUM ACETATE PH 4.75, 0.2 M AMMONIUM ACETATE, VAPOR DIFFUSION, HANGING DROP, temperature 291K
Unit Cell:
a: 43.856 Å b: 88.914 Å c: 176.405 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 2 2 21
Crystal Properties:
Matthew's Coefficient: 2.65 Solvent Content: 53.53
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.8490 49.0460 109841 5471 96.4100 0.1739 0.2087 35.1342
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.8490 50.0 96.400 0.052 ? 10.480 ? 113930 109841 2.0 -3.000 37.411
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.8490 1.960 96.200 ? ? 2.070 ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID29 0.97627 ESRF ID29
Software
Software Name Purpose Version
XSCALE data scaling .
PHASER phasing .
DM phasing .
PHENIX refinement 1.7.2_869
PDB_EXTRACT data extraction 3.10
DNA data collection .
XDS data reduction .
Feedback Form
Name
Email
Institute
Feedback