X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 293 0.2 M lithium sulfate, 10% w/v PEG 8000+, 10% w/v PEG 1000, pH 7.5, vapor diffusion, hanging drop, temperature 293K
Unit Cell:
a: 130.050 Å b: 130.050 Å c: 70.190 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: I 41 2 2
Crystal Properties:
Matthew's Coefficient: 3.00 Solvent Content: 58.98
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 1.95 32.79 22324 1141 100.0 0.176 0.206 35.54
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.946 91.959 100.0 ? 0.08000 23.3000 14.400 ? 22341 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.95 2.05 100.0 ? 0.42000 1.800 13.80 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON ESRF BEAMLINE ID14-2 ? ESRF ID14-2
Software
Software Name Purpose Version
MOSFLM data reduction .
SCALA data scaling 3.3.9
PHENIX refinement 1.7.2_865
PDB_EXTRACT data extraction 3.10
BALBES phasing .