X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 293 50mM Tris, 1.9M Ammonium sulfate, pH 8.0, VAPOR DIFFUSION, HANGING DROP, temperature 293K
Unit Cell:
a: 233.057 Å b: 268.453 Å c: 73.259 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 2
Crystal Properties:
Matthew's Coefficient: 2.40 Solvent Content: 48.77
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT ? 2.70 30.01 120656 2501 97.8 0.220 0.275 32.16
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.700 30.01 94.9 0.10900 0.10900 14.1000 5.300 ? 120656 ? ? 29.2
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.70 2.85 98.0 ? 0.38000 2.000 5.40 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON MAX II BEAMLINE I911-2 ? MAX II I911-2
Software
Software Name Purpose Version
SCALA data scaling 3.3.9
PHENIX refinement 1.6.4_486
PDB_EXTRACT data extraction 3.10
MOSFLM data reduction .
PHASER phasing .