X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 8.0 277 25% PEG 4K, 0.1 M Tris pH 8.0, 0.2 M sodium acetate, 0.1 M Li2SO4, VAPOR DIFFUSION, HANGING DROP, temperature 277K
Unit Cell:
a: 45.907 Å b: 75.195 Å c: 115.416 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 1.97 Solvent Content: 37.70
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT THROUGHOUT 2.00 50.00 24215 1304 91.99 0.16399 0.21152 27.342
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.0 50 91 ? ? ? ? ? 25533 2.0 2.0 ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.000 2.052 63.44 ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 80 K
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON APS BEAMLINE 17-BM 1.1000 APS 17-BM
Software
Software Name Purpose Version
HKL-2000 data collection .
PHASES phasing .
REFMAC refinement 5.6.0117
HKL-2000 data reduction .
HKL-2000 data scaling .